Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

Village of Caledonia (WI)

Wisconsin Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
Wet Stamps RequiredDigital Structural
Fire Setback Enforced0

Codes

NEC Code Version
2017
Code List

2017 NATIONAL ELECTRICAL CODE SPS 320-325 WISCONSIN UNIFORM DWELLING CODE SPS 316 WISCONSIN FIRE CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
1
Revision Required
0
New Planset Required For Module Swap
0

Stamps

Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
0
Setback Notes

Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
30
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

Standard

Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,Line Side Taps,PV Breaker,Meter Adapter
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

This AHJ uses Department of Safety and Professional Services for governing codes. Links to relevant chapters can be found here. Chapter SPS 320 (https://docs.legis.wisconsin.gov/document/administrativecode/ch.%20SPS%20320) Chapter SPS 325 (https://docs.legis.wisconsin.gov/document/administrativecode/ch.%20SPS%20325) Chapter SPS 325 Appendix A (https://docs.legis.wisconsin.gov/document/administrativecode/ch.%20SPS%20325%20Appendix%20A) Chapter SPS 325 Appendix B (https://docs.legis.wisconsin.gov/document/administrativecode/ch.%20SPS%20325%20Appendix%20B) Chapter SPS 325 Appendix C (https://docs.legis.wisconsin.gov/document/administrativecode/ch.%20SPS%20325%20Appendix%20C) Chapter SPS 316 (https://docs.legis.wisconsin.gov/document/administrativecode/ch.%20SPS%20316)

Ground mount

Ground Mount Fencing Required
Mesh/Scrim