SCE - Southern California Edison
Net Metering Allowed0
NEM TypeN/A
Supply Side Taps Allowed1
Line Taps Allowed0
Load Taps Allowed0
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- 0
- NEM Type
- N/A
- TOU Utility
- 1
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Avoided Cost
- Net Excess Generation Notes
Excess credits at the end of each month roll over from month to month within the annual true-up period. At the end of each annual true-up period, any remaining kWh credits are paid at the rate set by the CA CPUC, typically between $.02-$.04/kWh.
- Rebates Offered
- 1
- Deregulated
- 0
- Allows Standby
- 1
Interconnection & taps
- Approval Req To Install
- No
- Interconnection Level
- 1
- Supply Side Taps Allowed
- 1
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Tap Criteria
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Percentage
- Offset Value
- 200
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- Restriction Percent
- 150
- System Size Justification
- Load Justification
- System Offset Notes
- Offset Calc Tool
- CSI
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Utility Disconnect Switch
- Meter Spot Required
- 1
- Meter Spot Process
- . When prompted, press 1, 3, 0, 1.
- You can request 7 per call. Ask for the Construction Department when asked for your account number, and they will transfer you. Advise that you are upgrading for solar only - no additional loads (HVAC, pool, etc)
- GET SERVICE REQUEST NUMBER PER JOB!! This is an ID number and proof that you did request the meter spot. (Planning office numbers are uploaded to files below "SCE Service Centers.pdf".)
- Allowed Meter Adapter
- Tesla Backup Switch
Plans & docs
- Site Plan Reqs
All Projects
- BOS cannot be within 3 ft of the gas riser.
- BOS cannot be located under a Patio.
Battery Projects
- Specify battery make, model and location
Existing Systems
- Must show all equipment make, model and location for new and existing systems.
- SLD Reqs
Existing Systems
- Include the specific panel and inverter model on the line diagram.
- Include the specific panel and inverter model in the notes section on the right-hand side of the line diagram.
- Electric Service Reqs
- MSP must be min. 10" from a door, corner or window.
- Install Reqs
- Photos of AC Disconnect Switch or equipment specifications showing visible contact separation (should be visibly open showing separation of contacts, lockable, and 24 hours accessible to SCE personnel)
- Photo of Point of Connection
- A new main breaker must be compliant with the original MSP manufacturer's listing.
- 4-AWG or larger conductors require a lock ring and an insulated bushing when entering a box, cabinet or raceway.
- Placards
Existing Systems
- New and existing systems must be indicated specifically on the placard.
- Electrical Stamp Required
- 0
- Equipment Approvals
- California Energy Commission
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Label Page Notes
- Cover Page Notes
- Electrical Diagram Notes
- Rate Schedule Link
- link
- Website
- link
- Phone
- (866) 600-6290
Other details
- Restrict Inspection
- 0
- Revision Required
- 0
- Mod Swap Requires Planset
- 0
- Address ID
- 108553
- Express Planset Eligible
- Yes