United Power
Net Metering Allowed1
NEM TypeAnnual
Line Taps Allowed0
Load Taps Allowed0
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Annual
- TOU Utility
- 1
- Post Solar Billing Method
- Net Metering
- Solar Export Type
- N/A
- Net Excess Generation Notes
- On a monthly basis, excess kwh’s will be rolled over to the next month for future use at the member’s applicable rate. A member’s minimum bill will be the associated fixed service & facility charge for that member’s rate.
- On an annual basis (expressed in an Apr - Mar period), a member that continues to have excess generation will be cashed out at the wholesale energy rate.
- Rebates Offered
- 0
- Deregulated
- 0
- Allows Standby
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 1
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 25
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Percentage
- Offset Value
- 200
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- Utility Specific Adjustments
- For New Homes Sizing Method: Please see the "USE FOR UP SQ FOOTAGE - 2018 CO Residential New Estimator Table.pdf" attached in files
- System Size Justification
- Load Justification
- System Offset Notes
- Offset Calc Tool
- N/A
Metering & disconnect
- Production Meter Required
- Yes
- Production Meter Position
- Inv-PM-Disco-POI
- Production Meter Labeling
- Production Meter
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Meter Spot Required
- 1
- Meter Spot Process
- Schedule 3 days ahead for a disconnect for MPUs.
- No forms need to be filled out.
- Allowed Meter Adapter
- ConnectDER
Plans & docs
- Site Plan Reqs
- AC Disconnect must be on building's exterior
- SLD Reqs
- If the project includes MPU, minimum Type 2 SPD must be installed.
- Label Production Meter: RINGLESS 200A AMI PRODUCTION METER
- 200A Production Meter requires #6 Wire Minimum on the Line and Load Side.
- Only one Production Meter allowed per house/property.
- Battery: Inv > AMI PRODUCTION METER > Gateway > AC Disconnect > POI
- Electric Service Reqs
Surge Protection Requirements
- NEC 2020 §230.67 requires Type 1 or Type 2 surge-protective devices (SPD) for all new or replaced electrical equipment.
- If the project includes an MPU, a minimum Type 2 SPD must be installed.
- Install Reqs
- Electrical Stamp Required
- 0
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Rate Schedule Link
- link
- Website
- link
- Phone
- 303-637-1390
Other details
- Restrict Inspection
- 0
- Revision Required
- 1
- Mod Swap Requires Planset
- 1
- Address ID
- 108066
- Express Planset Eligible
- No