Georgia Power
Net Metering Allowed0
NEM TypeN/A
Supply Side Taps Allowed1
Line Taps Allowed1
Load Taps Allowed1
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- 0
- NEM Type
- N/A
- TOU Utility
- 0
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Avoided Cost
- Net Excess Generation Notes
RNR-Instantaneous Netting:
- All Excess Energy will be credited at the Solar Avoided Energy Cost, summed monthly, and then used to reduce the customer’s total monthly bill.
- Rate changes year to year.
- Customers will be paid out per kW they produce rather than matching energy production to energy consumption.
Energy Offset Only:
- Customers will not receive any credit for generation that is exported.
- Rebates Offered
- 0
- Deregulated
- 0
- Allows Standby
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 2
- Supply Side Taps Allowed
- 1
- Line Taps Allowed
- 1
- Load Taps Allowed
- 1
- Tap Criteria
- Tap boxes not allowed
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 10
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 1
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- Utility Specific Adjustments
Goodleap Projects: (Including Battery)
- Goodleap has a 10kw AC limit - regardless of PV only or Backup
- Goodleap systems with TPW3 we will require AC coupling to limit the AC size to 10kw.
- Since TPW3 has a 7.6kw AC limit each - the max inverter we can use with it is a 7.6kw. (If we are using two TPW3 or a TPW3+Xpac we can use a single SE10k inverter)
- If the system size exceeds a 7.6k inverter (with one TPW3), we can do split pv system with 5.7k string on the TPW3, and 3.8k upstream of the gateway.
- No PCS or curtailment will be accepted.
- Existing systems are now DQ from Goodleap if sold after November 1, 2025.
All other finances can build AS SOLD
- System Offset Notes
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Meter Spot Required
- 1
- Meter Spot Process
- If meter pull/TDR is required, call DROP LINE hit option 1 to request a work order to be created for approval to have meter pulled.
- There will be a 3-business day turn around for approval, and date and time will be provided for Utility tech to go pull meter.
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
All Jobs:
- Add a note specifying the POI
- AC disconnect must be within 10' of utility meter.
- SLD Reqs
All Jobs
- NO METER CAN TAPS
Existing Systems
- Show total system AC and DC capacity (existing and new)
Battery Projects
- Label the open transmitter relay in the MID device (add leader pointing to relay switch)
- Add a note PV SYSTEM IS “NON-EXPORTING” If AC System Size > 10 KW
- Install Reqs
All Jobs:
- Do not place system in Stand-by Mode. Leave Inverter on, and the turn the AC disconnect off.
- This Utility's inspectors will test the system, and if they cannot remove Stand-by they will fail the Witness Test.
- Electrical Stamp Required
- 0
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Electrical Diagram Notes
All Jobs [AC disconnect is 24/7 accessible to GP // 30’ wide access route for entirety of ICF Site; 15’ of clearance on all sides around transformer.]