ComEd - Commonwealth Edison Co
Spot something wrong?
Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.
Report a correction Net Metering AllowedYes
NEM TypeAnnual
Supply Side Taps AllowedYes
Line Taps AllowedYes
Load Taps AllowedYes
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- Yes
- NEM Type
- Annual
- TOU Utility
- Yes
- Post Solar Billing Method
- Net Metering
- Solar Export Type
- N/A
- Net Excess Generation Notes
- For customers purchasing energy from ComEd at fixed-prices, net metering credits are measured in kWh and used to reduce energy supply and other kWh-based charges. Net metering credits carried over from prior billing periods can be used to reduce future energy supply and other kWh-based charges until the end of the annual period specified on the Net Metering Election Form.
- For customers purchasing energy from ComEd at hourly prices, net metering credits are based on the price of power during the hours excess energy is produced and are reflected as a monetary credit on your energy bill.
- Rebates Offered
- Yes
- Deregulated
- Yes
- Allows Standby
- No
Interconnection & taps
- Approval Req To Install
- Yes
- Supply Side Taps Allowed
- Yes
- Line Taps Allowed
- Yes
- Load Taps Allowed
- Yes
- Tap Criteria
- Lineside Taps are approved inside meter cans for PV-Only projects (We cannot tap in the meter can on battery projects, unless it uses a Tesla Backup Switch)
- Meter can needs to be an 8" x 12" size in order to house the tap
- Taps also allowed on underground pedestal-style meters
- If the meter can is ringed, or if it is a stand-alone meter with no can, a meter upgrade will be required. If we replace the meter can then it needs to be ringless
Battery Projects
- Tesla Backup Switch is Allowed
- Design with backup switch only. If a gateway is required, provide an explanation in the design notes
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- No
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- No
- System Size Includes Existing Systems
- No
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- Utility Specific Adjustments
- If the customer does not have 12 months of consecutive usage, the system will need to be sized using the Delivery Service Class chart..
- Inverter Oversize Restrictions
- Yes
- Restriction Percent
- 150
- System Offset Notes
- Offset Calc Tool
- PV Watts
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Utility Disconnect Switch
- Meter Spot Required
- No
- Meter Adapter Requirements
- Allowed Meter Adapter
- ConnectDER,Tesla Backup Switch
Plans & docs
- Site Plan Reqs
All Projects
- Plans must exactly match the account holder's name and service address on the utility bill - All pages of the plan set (including Unit #)
- ComEd will not kickback based on AC Disco labeling per staff.
Battery
- Battery model has to be specified for SEEB and PW3 - (ex. UBAT-10K1PS0B-03)
- SLD Reqs
All Projects
- Inv > AC Disco > POI
- 10kW to 25kW systems registered with GATS must utilize a meter that meets ANSI C.12 standards. Certified, refurbished meters are allowed.
- See file: Electrical in Illinois for guidelines on creating plans.
- Rigid Conduit (IMC) is required
- ComEd will not kickback based on AC Disco labeling per staff.
Battery
- Tesla Backup Switch is Allowed - Please remove the verbiage "METER ADAPTOR" on the SLD next to the Backup Switch - DESIGN WITH BACKUP SWITCH ONLY, DO NOT USE THE GATEWAY UNLESS ABSOLUTELY NECESSARY, AND LEAVE NOTES AS TO WHY.
- For SEEB, Battery model has to be specified - UBAT-10K1PS0B-03
- Electric Service Reqs
- Roof plates used as service attachments are no longer supported by ComEd.
- All service revisions will require an exterior emergency disconnect and whole-home surge protection.
- Install Reqs
- .
- Electrical Stamp Required
- No
- Meter Num Req SLD 3LD
- No
- ESID Num Req SLD 3LD
- No
- Site Plan Notes
- Label Page Notes
- Cover Page Notes
- Electrical Diagram Notes
- Rate Schedule Link
- link
- Website
- link
- Phone
- (630) 576-8158
Other details
- Revision Required
- Yes
- Mod Swap Requires Planset
- Yes