South Central Power Company

Ohio Utility Interconnection & net metering rules

Spot something wrong?

Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.

Report a correction
Net Metering AllowedNo
NEM TypeN/A
Line Taps AllowedNo
Load Taps AllowedNo
MPU Rules<ul><li>If removal of a meter is necessary during the interc
AC Disconnect RequiredYes

Net metering & export

Net Metering Allowed
No
NEM Type
N/A
TOU Utility
No
Post Solar Billing Method
Export Rate
Solar Export Type
Avoided Cost
Solar Export Value Notes
will be purchased by Buckeye power @ Avoided cost
Net Excess Generation Notes

The Power Company shall use an hourly kWh period to measure the Consumer’s net production. The net production output shall be measured by determining during each such period the production in kilowatt-hours (kWh) of the Electric Generating Facility in excess of the requirements of the Consumer’s electric consumer facilities. Any such output of the Electric Generating Facility in excess of the requirements of Consumer’s electric consuming facilities shall be sold to Buckeye Power, Inc. The Power Company shall bill the net electric usage pursuant to the Power Company’s applicable Net Billing Rate Schedule, and credit the net electric output at Buckeye’s purchase rate.

Rebates Offered
No
Deregulated
Yes
Allows Standby
Yes

Interconnection & taps

Approval Req To Install
Yes
Line Taps Allowed
No
Load Taps Allowed
No
MPU Rules
  • If removal of a meter is necessary during the interconnection installation, contact them Power at to schedule a temporary disconnect
Automatic Transformer Upgrade Size
0
Meter Aggregation Allowed
No

System size & offset

System Size Restrictions
25
System Size Restriction Type
AC kW
System Size Battery Included
No
System Size Includes Existing Systems
No
Offset Type
Combination
Offset Value
120
Offset Calculation Basis
Historical
Offset Calculation Period
12
Industry Standard Watts Sqft
2
Inverter Oversize Restrictions
No
System Offset Notes


Offset Calc Tool
Historical Usage

Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
AC Disconnect Required
Yes
AC Disconnect Labeling
Visible Lockable Labeled Disconnect
Meter Spot Required
Yes
Allowed Meter Adapter
None

Plans & docs

SLD Reqs
  • The diagram must include the design on the member’s side of the meter, including a visible, lockable AC disconnect.

TAPS

  • South Central Power does not permit hard tapping or tap connectors of service entrance conductors prior to the first means of disconnect. If you choose to do a source-side connection, it may be established through approved bus lug connectors.
  • Prefers load-side interconnection
Electric Service Reqs


Placards

NEC standards

Electrical Stamp Required
No
Equipment Approvals
California Energy Commission
Meter Num Req SLD 3LD
No
ESID Num Req SLD 3LD
No
Website
link
Phone
(800) 282-5064

Other details

Revision Required
No
Mod Swap Requires Planset
Yes