GP&L - Garland Power & Light
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Monthly
- TOU Utility
- 0
- Post Solar Billing Method
- Net Metering
- Solar Export Type
- Fixed kWh
- Solar Export Rate
- 0.0669
- Net Excess Generation Notes
Solar panels first supply power to the home or business. When the solar panels produce more power than the premise is using, the electricity is sent onto the GP&L system. If the customer needs more power than the PV system can supply, electricity will be delivered from the GP&L system.
The bi-directional meters provide two different readings:
- The kilowatt (kWh) of electricity produced and delivered from the PV system to the GP&L electric system since the meter was installed. It indicates energy produced by the PV system in excess of what was used by the customer.
- The kilowatt (kWh) of electricity delivered from the GP&L electric system to the customer since the meter was installed. It indicates energy delivered to the customer in excess of the PV system production.
These power flow readings are provided on your monthly bill and are netted out to determine the monthly energy consumption.
- Rebates Offered
- 0
- Deregulated
- 1
- Allows Standby
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 1
- Supply Side Taps Allowed
- 1
- Line Taps Allowed
- 1
- Load Taps Allowed
- 1
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 10
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- System Offset Notes
System Size Limit: 10kW AC
- Offset Calc Tool
- N/A
Metering & disconnect
- Production Meter Required
- No
- AC Disconnect Required
- Yes
- Meter Spot Process
11/20/19 - Regarding disconnects: Anyone (does not need to be an electrician) can call, 30 mins prior for disconnect.
Please call them at for any issue including disconnect.
Also, Building Inspections at will answer questions about the side tap
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
Layout of the panels
Proposed meter location
Manual disconnect switch
- SLD Reqs
Electrical diagram must be signed/sealed by an electrical engineer
The distance between the AC Disco and the meter needs to be stated
The configuration of all distributed generation equipment
Current and potential circuits
Protection and control schemes signed by a Professional Engineer and bearing his/her seal.
Metering equipment, existing or new, must be 200amp minimum enclosure for fitment of utility installed bi-directional meter. (200amp service not required, specifically the enclosure.)
Line side tap conductors must end in a breaker or fuses not in mlo lugs in the panel.
- Electric Service Reqs
(Utility) Metering equipment, existing or new, must be 200amp minimum enclosure for fitment of utility installed bi-directional meter. (200amp service not required, specifically the enclosure.)
Milbank tap connector kits are allowable.JMU
- Install Reqs
Disconnect required to be within 10 FT of the electric service meter
the system must be on and producing at the time of utility inspection for the Anti-islanding test.
- Placards
AC Disconnect:
Required to have a placard 3/8" or larger that states "Generator Disconnect Switch" (Utility did not provide examples)
- Electrical Stamp Required
- 1
- Meter Num Req SLD 3LD
- 0
- Website
- link
- Phone
- 972-205-2671; 972-205-2929
Other details
- Restrict Inspection
- 0
- Revision Required
- 1
- Mod Swap Requires Planset
- 1
- Address ID
- 108105
- Express Planset Eligible
- Yes