New Richmond Utilities
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Monthly
- TOU Utility
- 0
- Post Solar Billing Method
- Net Metering
- Net Excess Generation Notes
For systems 20 kW or less, any energy exported to the grid will be credited at the full retail rate. At the end of each billing cycle, if there is a remaining credit balance, it will over indefinitely until it is fully used. If the credit balance exceeds $25, the customer has the option to request a payout.
- Rebates Offered
- 1
- Deregulated
- 0
- Allows Standby
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 20
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- Inverter Oversize Restrictions
- 0
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
- Street address of DG facility
- Adjoining street name
- Electric service entrance
- Electric meter
- Interface equipment
- Location of major equipment
- Location of interconnect disconnect switch
- SLD Reqs
- Generator or inverter
- Point where DG facility is electrically connected to the customer’s electrical system
- Point of common coupling
- Lockable interconnection disconnect switch (outside)
- Method of grounding, including generator and transformer ground connections
- Protection function and systems
- Equipment Approvals
- California Energy Commission
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Rate Schedule Link
- link
- Website
- link
- Phone
- (715) 246-4167
Other details
- Restrict Inspection
- 0
- Revision Required
- 1
- Mod Swap Requires Planset
- 1
- Address ID
- 167900
- Express Planset Eligible
- Yes